Retaining previously held values in simulink
9 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I have a simulink model that is run using a code in a loop in consecutive time-steps. However, there's a problem, that the model resets itself before each new time-step (loop). I was wondering if there is an option for the model to NOT RESET itself before new iteration, in other words, I want all signals to keep (retain) their last held values from previous iteration. Thanks.
0 Kommentare
Antworten (1)
Jonas
am 13 Feb. 2020
Bearbeitet: Jonas
am 13 Feb. 2020
It is not completely clear to me what your set-up looks like, but you may want to investigate 'Enabled Subsystems'. You can set each output to be 'held' or 'reset' when enabling.
2 Kommentare
Jonas
am 14 Feb. 2020
I assume that each iteration you do, is running the simulation model, stopping it, and starting it from stratch. What I would do is put the part that you want to iterate inside an Enabled Subsystem but the plant model not. Then you could enable and reset the iterative part that you DO want to reset with a certain clock or trigger. The plant model however just keeps running.
This means that instead of running, stopping and restarting your whole Simulink model, you run it once.
Hope this is somewhat clear and inspiring.