Simulation of PMSM Current Control using FCS-MPC
11 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Hi everyone
I'm trying to control a pmsm current using finite control set MPC, when I'm using PMSM model in simscape everything is fine and currents can track id and iq (currents in dq reference frame) but the problem is PMSM model is based on modified park transform (90 degree behind phase a) and our calculations are based on the original park.
when I change the PMSM model park transform to original park, the results change and FCS-MPC does not work properly.
does anybody have this problem?
Thank you in advance
1 Kommentar
ty
am 14 Aug. 2025
can you send the simulation and the script please????appreciate! 1850478638@qq.com.
Antworten (1)
Shang-Chuan Lee
am 10 Jun. 2022
Hi Hossein,
It sounds to me the rotor angle definition of PMSM isn't aligned with your control algortihm where the Park/Clarke Transform on the dq-axis. I would suggest first check the current signals to the "Park Transform" block as well as the "Clarke Transform" block from the current measurement signals.
Best,
Shang-Chuan
0 Kommentare
Siehe auch
Kategorien
Mehr zu Switches and Breakers finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!