Filter löschen
Filter löschen

Downsampling of RPM traces

2 Ansichten (letzte 30 Tage)
MAT-Magic
MAT-Magic am 10 Jan. 2020
Bearbeitet: MAT-Magic am 22 Jan. 2020
Hi,
I have RPM trace signal (respiratory data) sampled at 26 Hz. I want to downsample RPM trace signal to 5.2 Hz. Does anyone know how to downsample this trace signal to 5.2 Hz?
Thanks in advance.

Akzeptierte Antwort

Star Strider
Star Strider am 10 Jan. 2020
I assume that the signal is sampled regularly, and a fixed sampling interval.
Use the Signal Processing Toolbox resample function. It will do exactly what you want.
A prototype call to it would be:
RPMrs = resample(RPM, 52, 260);
so the output will be sampled at 5.2/26 of the original rate.
To calculate a new time vector for it, use the linspace function.
Note that if it is not uniformly sampled, first follow the procedure in Resample a Nonuniformly Sampled Data Set, then do the rate resampling.
  15 Kommentare
MAT-Magic
MAT-Magic am 22 Jan. 2020
Thank you so much Sir !!!
Star Strider
Star Strider am 22 Jan. 2020
As always, my pleasure!

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (0)

Produkte

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by