Can only choose pi radians / sample in Passband frequency, not Hz.
    8 Ansichten (letzte 30 Tage)
  
       Ältere Kommentare anzeigen
    
    Ahmet Alper Özkan
 am 19 Okt. 2019
  
    
    
    
    
    Bearbeitet: Daniel M
      
 am 19 Okt. 2019
            As the title says. I'm trying to use preprocessing options in Signal Analyzer and it doesn't present me with a Hz option when inputting the passband frequency, what could the reason be?
0 Kommentare
Akzeptierte Antwort
  Daniel M
      
 am 19 Okt. 2019
        
      Bearbeitet: Daniel M
      
 am 19 Okt. 2019
  
      This toolbox uses the convention that unit frequency is the Nyquist frequency, defined as half the sampling frequency. The cutoff frequency parameter for all basic filter design functions is normalized by the Nyquist frequency. For a system with a 1000 Hz sampling frequency, for example, 300 Hz is 300/500 = 0.6. To convert normalized frequency to angular frequency around the unit circle, multiply by π. To convert normalized frequency back to hertz, multiply by half the sample frequency.
0 Kommentare
Weitere Antworten (0)
Siehe auch
Kategorien
				Mehr zu Matched Filter and Ambiguity Function finden Sie in Help Center und File Exchange
			
	Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!