The Computed sample time
128 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Youssef Toubla
am 28 Aug. 2019
Beantwortet: Abhishek saini
am 4 Mär. 2022
Hi,
i get this error:
The computed sample Time 2E-09 is not an integer multiple of the fixed step size 1E-08. the period, pulse width and phase delay parameters of this block need to be integer multiples of the fixed step size.
can anyone help
Reagrds
YT
4 Kommentare
sruthi kesav
am 4 Mai 2020
Bearbeitet: sruthi kesav
am 4 Mai 2020
Hi,
i get this error:
The computed sample time (1.25E-06) is not an integer multiple of the fixed step size (1E-05). The period, pulse width and phase delay parameters of this block need to be integer multiples of the fixed step size.
Can anyone help me.Thanks in advance.
Regards,
Shruthi.D
Fangjun Jiang
am 4 Mai 2020
If the step size is 1 second, the sample time of any block could be 1, 2, 5, 10, etc. It can't be 2.3, 10.5 or smaller than 1 like 0.5, etc.
The easiest way for you is to change the step size to be 1.25E-6 if possible. You may have further issue though.
Akzeptierte Antwort
Fangjun Jiang
am 29 Aug. 2019
Based on your specification of Period (secs) and Pulse Width (% of period), Simulink calculated that the time incremental needs to be as small as 2E-09. But your fixed step size (1E-08) is larger. That is the error.
Double check your specification. Please note that if you want to specify 5% duty cycle, you should specify it as 5, not 0.05.
0 Kommentare
Weitere Antworten (1)
Abhishek saini
am 4 Mär. 2022
The computed sample time (0.0004) is not an integer multiple of the fixed step size (0.0084). The period, pulse width and phase delay parameters of this block need to be integer multiples of the fixed step size