Input ports (1, Action) If Action Subsystem' are involved in the loop?
154 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I am trying to simulate a closed loop cooling system using simulink but facing this error continously.
If anyone can help me with this would be of great help?
I have uploded the file,if anyone can please run it and share the trouble shooting measures willbe of greta help.
I ahve uploded the mat variable file for initialization parameters of the model
2 Kommentare
Murugan C
am 21 Aug. 2019
I couldn't able to open the model. Because you designed in Simulink 2017a, So can you please upload 2016b simulink model or below version.
Antworten (1)
Divya Yerraguntla
am 25 Sep. 2019
Hi Adit,
I could see an algebraic loop formed in your model by the signal coming to Total_pressure_BP input of Pump 1 subsystem. This is actually causing the issue. Try adding a Unit Delay block to the signal coming to Total_pressure_BP block.
For more information about identification and removal of algebraic loops have a look at these links:
Also in order to solve algebraic loops in models containing continuous blocks you could go through this link:
Hope it helps!
1 Kommentar
Satya Prakash
am 7 Okt. 2021
Is there any other method to handle signals without adding delay block?