Frequency response estimation take too long time - couple of hours?
6 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
when I use Linear analysi tool to do Frequency response estimation to sweep input frequece from [10Hz 15K], It
takes more than 4 hours to get estsys1 data? even when my system 'a simple PFC block' is stopped, Linear analysis tool
still show 'Simulating the model' running, why?
0 Kommentare
Antworten (1)
Siddharth Jawahar
am 14 Okt. 2020
Bearbeitet: Siddharth Jawahar
am 14 Okt. 2020
Hi Jian,
Frequency response estimation can be slow especially if you are using sinestream perturbation signals for power electronics application like power factor correction. This can depend on factors such as sample time of the model, number of frequency points for your estimation. Recently we have introduced PRBS perturbation signals which lead to faster estimation times, specifically for such power electronics applications. Please see if you you can get good results by using this signal compared to sinestream signals. Having the sinestream results can be a good sanity check to compare your PRBS estimation results.
Some useful documentation that you might find helpful to start:
https://www.mathworks.com/help/slcontrol/ug/prbs-input-signals.html?s_tid=srchtitle
https://www.mathworks.com/help/slcontrol/ug/frequency-response-estimation-for-power-electronics-model-using-prbs.html?s_tid=srchtitle
HTH,
Sid
1 Kommentar
MUHAMMAD AJMAL
am 9 Aug. 2023
@Siddharth Jawahar I am trying to implement this comand but not get result 'Estsys_prbs1.frequency'.