ERROR: floating constant is out of range

10 Ansichten (letzte 30 Tage)
Hai Nguyen
Hai Nguyen am 5 Mai 2019
Kommentiert: Dajr Alfred am 15 Mai 2023
I have created a algorithm in Simulink. I tried to implement this model to TI TMS320F28379D LAUNCHXL board embedded target. When I try to build the model, I receive the following error messages.
Capture.JPG
This is one of the code segments that caused error
Capture1.JPG
  1 Kommentar
Walter Roberson
Walter Roberson am 29 Okt. 2022
Bearbeitet: Walter Roberson am 29 Okt. 2022
I wonder where that constant comes from; too bad it isn't documented. It happens to be 0x1cc0000000000000 but that does not tell me anything about what it represents.
Ah... with further checking I see that it is
format long g
eps(sqrt(realmin))
ans =
3.31216864211124e-170
and that suggests its replacement value should be
eps(sqrt(realmin('single')))
ans = single
1.29247e-26

Melden Sie sich an, um zu kommentieren.

Akzeptierte Antwort

Mike Hosea
Mike Hosea am 7 Mai 2019
That number is well within the range of IEEE double precision floating point numbers, but the TI TMS320F28379D has native 32bit IEEE single precision floating point. I'm not sure what the C compiler for it does with double precision data, but based on what you have shown, it doesn't seem to support IEEE double precision floating point, even in emulation. Try using single precision.
  3 Kommentare
Mike Hosea
Mike Hosea am 29 Okt. 2022
You could start here.
Dajr Alfred
Dajr Alfred am 15 Mai 2023
The easiest way to accomplish this with simulink is to use the Single Point Converter in the Apps tab