Trying to model fault currents in a theoretical private 11kv network. Simscape Electrical is missing a DY11 transformer. It does have a Ddy11 which isn't helpful.
Other searches point me towards the 2 winding transformer in the specilised power systems tools. This doesn't link to the Electrical toolbox.
What am I missing

Akzeptierte Antwort

Joel Van Sickel
Joel Van Sickel am 2 Sep. 2020
Hello Joshua,
the two winding transformer in simscape electrical can be configured with wye/floating, wye/grounded, wye neutral exposed, delta 1 and delta 11. These can be configured in any combination of these on both sides to achieve that configuraiton that you would like.
Regards,
Joel