PUSCH Throughput Conformance Test got throughput 0 with ue.RC = 'A4-3'

In this example, changed the FRC from A3-2 to A4-3, then Run this script, got 0 throughput for all SNR values,not sure anything others needed to change or not?
UE Configuration
User Equipment (UE) settings are specified in a structure form.
ue.RC = 'A3-2'; % FRC number
BRs,
Scott

 Akzeptierte Antwort

Graham Freeland
Graham Freeland am 6 Feb. 2019

0 Stimmen

Should be good, run it and check the throughput curve trend.

Weitere Antworten (2)

Graham Freeland
Graham Freeland am 5 Feb. 2019
Bearbeitet: Graham Freeland am 6 Feb. 2019

0 Stimmen

Hi,
You'll have to move the SNR range of the simulation up since the code rate is now a lot higher, going from 1/3 (A3-2) to 3/4 (A4-3). You'll also need to increase the length of the simulation to get reliable results (the simulation example code is set to a short run to make it practical in the first instance).

1 Kommentar

Thanks for the answer, do we have recommended range of simulation length for different code rate?

Melden Sie sich an, um zu kommentieren.

Graham Freeland
Graham Freeland am 6 Feb. 2019

0 Stimmen

The simulation length will generally depend on the channel doppler. A4-3 is used in reference tests using EPA5 or EVA70 channels. The standard specifes very long simulations for RAN4 tests but 1000-5000 subframes may be sufficient for reasonable convergence.
Graham

1 Kommentar

So NFrame 100 to 500 shall be sufficient, to A4-3 EPA5 channel, right?

Melden Sie sich an, um zu kommentieren.