Linearization error "NaN's cannot be converted to logicals"

66 Ansichten (letzte 30 Tage)
I get the error. " NaN's cannot be converted to Logicals" when trying to linearize my model. The model runs actually with no problem. the problem arises only when linearizing the model in control design. I don't know what exactly simulink does during linearazation that causes this error.

Akzeptierte Antwort

Adam Danz
Adam Danz am 9 Aug. 2018
This will replicate your error:
v = [1 0 1 1 0 NaN 0 1 0 0];
logical(v)
Error using logical
NaN's cannot be converted to logicals.
My guess is that you're using logical() to convert a variable with 0s and 1s that also have NaN values.
If that's the case, you need to decide whether NaNs should be a 0 or a 1. In this example, I set NaNs to 0.
v = [1 0 1 1 0 NaN 0 1 0 0];
v(isnan(v)) = 0;
logical(v)
Or you can remove the NaNs
v = [1 0 1 1 0 NaN 0 1 0 0];
v(isnan(v)) = [];
logical(v)
  4 Kommentare
Hossein Rezazadeh
Hossein Rezazadeh am 9 Aug. 2018
Ok I got it. Apparently during the linearazation some numerical perturbation is fed to the block as input which causes "NAN" at the block output and this was triggering this error. adding v(isnan(v)) = []; to the block output solved the problem.
Tim
Tim am 8 Dez. 2018
Hi, could you please explain how exactly you added v(isnan(v)) = []; to the block output?

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (3)

Barton Bacon
Barton Bacon am 24 Okt. 2023
This just happened to me and the culprit was a square root block I had recently added to a simulation.... believe it or not. Changing the square root block to a power block and using .5 as the exponent for some reason allowed the linearization to proceed without the "NaN's cannot be converted into logicals" error. MATHWORKS what the heck is going on in the square root and reciprocal square block that would produces this problem in linearization? Those blocks linearize fine by themshelves in a their own block diagram. In a complicated simulation, not so much apparently.

Welid Benchouche
Welid Benchouche am 4 Jan. 2019
hello guys, can you please help me , i get the same error on model predictive control when linearizing Rc=0.15
  2 Kommentare
Hossein Rezazadeh
Hossein Rezazadeh am 4 Jan. 2019
Bearbeitet: Hossein Rezazadeh am 4 Jan. 2019
This happens in MPC when your model sends "NaN" to the "mo" inport of the MPC block.
As you have integrators in your model they should be responsible for "NaNs".
Either change the operating point at which you are linearizing the model or change the solver or max step size.
Apicha Kittirattanachai
Apicha Kittirattanachai am 21 Aug. 2020
please kindly explain "integrators in your model they should be responsible for "NaNs" "
How are integrators setting for response the NaN value ?
My problem is appear in mpc toolbox when linearize of toolbox.
Thankyou.

Melden Sie sich an, um zu kommentieren.


Ahmed Elgohary
Ahmed Elgohary am 5 Mär. 2022
Bearbeitet: Ahmed Elgohary am 5 Mär. 2022
Well, i got the same error with model predictive control during linearization and i could solve the problem by changing the range of simulink operating point as shown at the figure. So it was from [0 1] and i made it from [0.1 1] for example as you want for the upper limit but the main problem was related to using zero for lower limit during the linearization.