I'm working in a Simscape Fluids system. I specified the fluid with the Hydraulic Fluid block but I have a custom block in who I need to reference the density as a variable so that if I change the temperature in the Hydraulic Fluid the density could change in the custom block.

Antworten (1)

Yoke Peng Leong
Yoke Peng Leong am 14 Mai 2018
You can access the density following the example in this documentation: https://www.mathworks.com/help/physmod/hydro/ref/hydraulicfluid.html
For example, to access the density of Skydrol LD-4 at 50 degree Celcius:
>> props = sh_stockfluidproperties;
>> temp = 50;
>> [vis, den, bmod] = props.skydrol_ld_4.prop(temp);
where "temp" is the temperature (C), "vis" is the viscosity (m^2/s), "den" is the density (kg/m^3), and "bmod" is the bulk modulus (Pa).