I am trying to increase the performance of my model by using the multi-threading capabilities.
My model has a Signal Generation block which generates different types of signals like QPSK, Sine, FM for testing purpose. And this block is converted to a referenced model. When trying to execute the model with "Allow tasks to execute concurrently on target" = ON, Simulink throws the below error,
The block 'Cluster1_SigSources/Subsystem/Enabled Subsystem/SIG0001/Upsample' of type 'S-Function' is a multi-rate block. Currently Simulink supports only single-rate blocks of this type when the model is configured for concurrent execution.
I have attached the reference model. How do I overcome this issue? Any suggestions would help?
Matlab Version: 2017b
Akzeptierte Antwort
Weitere Antworten (1)
Mark McBroom
am 4 Mai 2018
0 Stimmen
Model will not update. What values are you using for the various parameters in the model?
4 Kommentare
Bhavanithya Thiraviaraja
am 7 Mai 2018
Mark McBroom
am 15 Apr. 2019
You need to make the folloowing configuration change in order for the model to update
From the Simulation Menu
-> Model Configuration Parameters
-> Solver
-> Uncheck the box: "Treat each discrete rate as a seperate task"
johnnynoc4sh
am 4 Apr. 2021
Bearbeitet: johnnynoc4sh
am 5 Apr. 2021
I have the same issue as the thread author. In my case the checkbox is disabled (see figure attached). Can you help me out? What is the reason for this behaviour?

Mark McBroom
am 6 Apr. 2021
You are using Simulink Real-Time. This option is always on for Simulink Real-Time. What version of MATLAB are you using? Which block is causing the issue?