Filter löschen
Filter löschen

Reset integrator no initial condition in Simulink

59 Ansichten (letzte 30 Tage)
Kars
Kars am 11 Jan. 2018
Beantwortet: Fangjun Jiang am 11 Jan. 2018
Hi,
I'm working on reset controllers and are trying to implement them in Simulink.
A reset controller uses an integrator which can reset itself. This can be implemented in Simulink using the 'External reset' option of the integrator element. The corresponding reset matrix can be implemented by showing the state port and by setting the Initial Condition Source to external.
In the image you see the an integrator, which resets to a partial value of the current state (through reset matrix R) when the input signal goes through zero. To implement the reset matrix R in the integrator, I have to set the Initial Condition Source to external. When I do this, I can no longer apply an initial condition.
Is there some way around to apply an initial condition at the start of the simulation?
  3 Kommentare
Kars
Kars am 11 Jan. 2018
Thanks for your answer, but it is irrelevant what the R matrix is. I've updated the question to clarify more.
Birdman
Birdman am 11 Jan. 2018
I will deal with this question tomorrow, hope you have time for this.

Melden Sie sich an, um zu kommentieren.

Antworten (1)

Fangjun Jiang
Fangjun Jiang am 11 Jan. 2018
I would insert a "Unit Delay" block after the "Gain" block and feed the output to "X0" port.

Produkte

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by