Common average refrencing (CAR) application on EEG signals.
19 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Maanvi Bhatnagar
am 28 Nov. 2017
Beantwortet: zaineb alhakeem
am 7 Mai 2019
I have a matrix of dimensions 450000*60 of a one class eeg signal. I have to apply Common average referencing (CAR) on it. Matrix dimension 45000*60 where 1:60 is the no. electrodes from 1 to 60 and 45000 is the total number of samples. Each trial consists of 1000 samples. This is to be calculated trial wise Can anybody help me with the code?
0 Kommentare
Akzeptierte Antwort
Debanjan Botthakur
am 16 Mär. 2018
Bearbeitet: Debanjan Botthakur
am 16 Mär. 2018
You can try
for i=1:60 signal2(:,i)=signal1(:,i)-mean(signal1,2); end
1 Kommentar
vinay kulkarni
am 2 Feb. 2019
hello i just want to ask that why do you take 2 there in mean(signal1,2) ?