How to define parameters of masked subsystem as tunable parameters (for code generation using Embedded coder)
Ältere Kommentare anzeigen
In simulink, how parameters provided to subsystem masks can be implemented as tunable parameters by RTW in generated code ? They don't appear in the window : 'Model Parameter Configuration'. So I can't define them as 'Global (tunable) Parameters'.
1 Kommentar
TAB
am 26 Apr. 2012
How you have defined the parametes? Are they defined as 'Simulink.Parameter'?
Antworten (2)
GENIN
am 27 Apr. 2012
1 Stimme
Titus Edelhofer
am 26 Apr. 2012
0 Stimmen
Hi Genin,
they should appear: if you use workspace variables for your subsystem mask parameters, those variables should appear so you can define them as tunable.
You need to mark them as tunable in the mask editor, though.
Titus