Error: cannot find space for target scope (R2016b)

1 Ansicht (letzte 30 Tage)
Stefano Buccelli
Stefano Buccelli am 5 Sep. 2017
It seems that the maximum number of target scope is 9. Is it correct? When I tried to add more than 9 target scopes I received this Error: cannot find space for target scope (on the target PC).
How can I view 60 traces in a 6x10 subplot? Host target scope?

Akzeptierte Antwort

Anh Tran
Anh Tran am 7 Sep. 2017
Hi Stefano,
The maximum number of target scope is 9, as stated in the Target Scope Usage documentation.
Each scope can take different signals. For example, you may have 6 target scopes. For each scope, you add 10 signals. This will effectively create a subplot on your Simulink Real-time Target screen. This example shows how to add 2 signal into a target scope. This link shows how to find signal indexes to pass into "addsignal" function
  1 Kommentar
Stefano Buccelli
Stefano Buccelli am 8 Sep. 2017
Thank you Anh, but no way to subplot just like in matlab. The signals will be superimposed in the same scope. Right?
Thanks again.

Melden Sie sich an, um zu kommentieren.