Simulink Linear Analysis Pole/Zero Plots
5 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Andres
am 15 Aug. 2017
Kommentiert: Sebastian Castro
am 16 Aug. 2017
Attached is the Simulink file I'm having problems with. I have this system controlled by a PID controller which gives me the desired response on 'Scope1'. Now I want to do some plots using "Analysis -> Control Design -> Linear Analysis...".
Here I get my bode and step responses plot, but when I go to the "I/O Pole/Zero Map" all the poles and zeros are on the right side (real positive values) which means the system is unstable and it seems to be contradictory from the step and bode plot that shows an stable system. Am I missing or misinterpreting anything? Here are the bode and step plots I get:


And this is the I/O Pole/Zero Map:

0 Kommentare
Akzeptierte Antwort
Sebastian Castro
am 15 Aug. 2017
Bearbeitet: Sebastian Castro
am 15 Aug. 2017
Based on the staircase step response, looks like your system is discrete.
This means that stability is inside the unit circle (circle of radius 1), which it is :)
- Sebastian