How to parameterize hydraulic valve with given manufacturer data sheet current vs flow rate?

Dear All How do i parameterize the 2 way and 3 way directional valve with given manufacturer data sheet current vs flow rate?

 Akzeptierte Antwort

The directional valve blocks have a Model Parameterization option in their dialogs. Two of those values let you enter your own data from, e.g., a datasheet.
From the documentation:
  • By area vs. opening table — Provide tabulated data of valve openings and corresponding valve passage areas. The passage area is determined by one-dimensional table lookup. You have a choice of two interpolation methods and two extrapolation methods.
  • By pressure-flow characteristic — Provide tabulated data of valve openings, pressure differentials, and corresponding flow rates. The flow rate is determined by two-dimensional table lookup. You have a choice of two interpolation methods and two extrapolation methods.
- Sebastian

2 Kommentare

Dear Castro
But in my data sheet valve displacement is not given. it has only current vs flow rate. so how does i do parameterize the valve.
Current? As in electric current, probably for a valve solenoid or something?
Is that then current vs. flow rate for a specific pressure? Because if so, you can probably back out the valve area as a function of input current...

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (0)

Kategorien

Mehr zu Simscape Fluids finden Sie in Hilfe-Center und File Exchange

Produkte

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by