Hi, I would like to implement an algorithm that fill the sldd from a model. The problem is that all the new object added have the default StorageClass Auto. How can I change it from command?

1 Ansicht (letzte 30 Tage)
Handles_cal=find_system(load_system('name_model'),'MaskPropertyNameString','CAL_BLK_NAME'); for i=1:length(Handles_cal) NAME=get(Handles_cal(i),'CAL_BLK_NAME'); myDictionaryObj = Simulink.data.dictionary.open('name_model.sldd'); sectionObj = myDictionaryObj.getSection('Design Data'); eval(sprintf('%s',[NAME '=Simulink.Parameter;'])) SignalName = Simulink.Parameter; SignalName.Value = 0; SignalName.Description='Description'; entryObj = addEntry(sectionObj,NAME,Simulink.Parameter); end

Antworten (1)

Donn Shull
Donn Shull am 16 Dez. 2017
Based on the code from your question you could create the parameters with Storage Class 'Imported Extern' as follows:
Handles_cal=find_system(load_system('name_model'),'MaskPropertyNameString','CAL_BLK_NAME');
myDictionaryObj = Simulink.data.dictionary.open('name_model.sldd');
sectionObj = myDictionaryObj.getSection('Design Data');
for i=1:length(Handles_cal)
NAME=get(Handles_cal(i),'CAL_BLK_NAME');
param = Simulink.Parameter;
param.CoderInfo.StorageClass = 'ImportedExtern';
entryObj = addEntry(sectionObj, NAME, param);
end