Simulink CAN timeout on embedded coder

1 Ansicht (letzte 30 Tage)
Marek Laszlo
Marek Laszlo am 14 Aug. 2016
Kommentiert: Marek Laszlo am 26 Mär. 2018
Hello,
I am coding in Simulink using c2800x package, Embedded coder and Vehicle Networks Toolbox. I am using CAN bus in my application. What I could not solve is how to detect that I didnt receive message in some time (timeout. My code model is encapsulated in function call block of 100hz. Each eCAN receive block has its function call that calls can unpack. I tried to use CAN unpack timestamp or cantimeout block but it doesnt work on target. So I was trying to run some type of down counter outside of the can handling function block and reset it always when can message is received. Actually I didnt found any way to reset the counter out of the CAN receive function call. Mostly it wanted to use transition block which is not suitable. Any suggestions how to get some type of normal simulink signal out of that call or other way around?
Thank You for help.
  3 Kommentare
Marek Laszlo
Marek Laszlo am 25 Okt. 2017
Hello,
Unfortunately I Didnt but I havent been looking for long because the project stopped at that time. So its still actual and would be happy if someone found how to deal with it.
Birdman
Birdman am 25 Okt. 2017
Hi Marek,
Can you share the simulink model(export to R2017a)?

Melden Sie sich an, um zu kommentieren.

Akzeptierte Antwort

Marek Laszlo
Marek Laszlo am 11 Mär. 2018
Bearbeitet: Marek Laszlo am 11 Mär. 2018
I used TI F28337 MCU that unfortunately doesnt have enhanced CAN module. Only the CAN module. This is unfortunately the reason why you cant receive a message timestamp even if you check it in your receive block.

Weitere Antworten (1)

Venkatesh Chilapur
Venkatesh Chilapur am 13 Mär. 2018
You can create a counter and reset it when you get a CAN message (from the function call of the CAN block or an interrupt). If the counter reaches the timeout value before a CAN message is received, then we can trigger a specific subsystem.
  1 Kommentar
Marek Laszlo
Marek Laszlo am 26 Mär. 2018
Thank You. I tried this and similar solutions but all failed on the function caller. The problem I could not solve and found other poeple asking for is how to reset the counter if you have only the function caller signal. The ports are imcompatible.

Melden Sie sich an, um zu kommentieren.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by