Simulink shows only the last 2 second of simulation time

5 Ansichten (letzte 30 Tage)
Alzapoa
Alzapoa am 9 Feb. 2012
Bearbeitet: Matt J am 6 Okt. 2013
Hello,
My Simulink model of an induction machine run about 2 second even if the simulation time is 20 sec. any idea on that?
The model is include of 3-phase to d-q model and then transforming to rotor reference model. the last step is deriving currents and applying the electrical torque and the mechanical torque has not been implemented yet. sot machine is working in no-load condition.
Regards,

Akzeptierte Antwort

Andreas Goser
Andreas Goser am 9 Feb. 2012
Please verify the scope setting: Parameters - Data History - Limit Data Point to last.
The default is it is checked and limited to 5000 points.

Weitere Antworten (0)

Kategorien

Mehr zu Building and Simulating Electronic, Mechatronic, and Electrical Power System Networks finden Sie in Help Center und File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by