Hi ;
I am using the models above. I am transmitting constant 100 to arduino, but I cannot read 100 on the receive scopes. I uploaded them separately and I also uploaded them in the same model. I couldn't read 100 in both ways. What could be wrong?
Thank you.
1 Kommentar
Qasim Alazze
am 5 Nov. 2016
hello : Have you gotten answer to your question or solved it??? if you did please help i have same problem ???
Antworten (1)
Venkatachala Sarma
am 8 Mär. 2016
To the top right of the 'Serial Transmit' and 'Serial Receive' blocks, it says 'ARDUINO'. This means that these blocks execute only inside ARDUINO hardware. You will not be able to use scopes to see the value sent or received by ARDUINO's serial port.
If you would like to transmit '100' serially to any hardware, you have to use 'Serial Configuration' and 'Serial Send' blocks in 'Instrument Control Toolbox'. Also to receive data serially from any hardware, use 'Serial Receive' in the same toolbox.
Hope this helps.