DAQ output randomly stops during continuous acquisition
12 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I am using the following code to output a constant voltage on channel 2 of a NI-PCI-6229 DAQmx device. I am using Matlab R2014a.
The problem is that after some period of time (sometimes 5-20 minutes), the device stops outputting the data continuously. After stopping, the device property: IsDone changes from 'flase' to 'true'. No error messages are generated upon completion.
devices = daq.getDevices;
s = daq.createSession('ni');
s.Rate = 10000;
s.IsContinuous = true;
addAnalogOutputChannel(s,'Dev1',2,'Voltage');
outputSignal = ones(s.Rate,1);
queueOutputData(s, outputSignal);
lh = addlistener(s, 'DataRequired', @(src,event) src.queueOutputData(outputSignal));
startBackground(s);
0 Kommentare
Antworten (3)
Rebecca Krosnick
am 22 Jan. 2016
I tried running your code in MATLAB R2014a (after creating the simulated device in NI MAX) and got the following output in MATLAB:
Warning: This change caused queued output data to be flushed. Use queueOutputData to queue data before starting the object.
Queue at least 5000 scans to output buffer. See NotifyWhenScansQueuedBelow for more information.
Did you not receive these errors? Try changing "outputSignal" to be a vector of 5000, as the error message suggests. For example:
outputSignal = ones(5000, 1);
Timothée
am 23 Mai 2018
Hi,
Did you solve this problem? I have the same issue. It stops after around 3.5 hours at 1MHz and this time seems reproducible.
3 Kommentare
Alex King
am 3 Dez. 2018
I'm also having this issue, with both the NI USB-4431 & USB-6356. I'm trying the suggestion from the other answer now, queuing more than 5000 samples of output data, even though I do not get this warning.
The time it stops seems to be reproducible here too (although different for the two cards). I will try to find time investigations with different sample rates. Perhaps it has to do with the buffer size of the card?
Windows 7 & 10, MATLAB R2018b
Hooman Sedghamiz
am 24 Aug. 2019
I have seen many questions in regards to DAQ session issues, some even dating back to 2016 but no answer so far. I am having the same issue and the output generation stops everytime at sample number 8196, even when I change the signal which is being outputed...
Is this a bug? Please be kind and resolve this!