Hello Mathworks-Team,
I am currently trying out Simulink Test and I've got a question about the Test Sequence Block. Is there any opportunity to stop the simulation, if a specified state is reached. I tried
set_param(ModelName, 'simulationcommand', 'stop')
but this doesn't work. The ModelName can't be read from workspace because it's a char array and Simulink Test only supports numerical or logical types.
1 Kommentar
Sai Vempati
am 8 Nov. 2018
How to stop a sweep rate input signal if a required freq is achieved! im unable to Stop Simulation with this stop block if a specified state is reached
my seems to be similar ! Thanks in advance for everyone
Sai
Antworten (4)
Young Ma
am 2 Aug. 2017
1 Stimme
Hi Patrick,
I understand from your description that you want to stop the simulation when a specific state is reached in Test Sequence block. This is not supported yet in R2017a. I'll communicate this with the relevant staff and hopefully this feature will be available in a future release.
A workaround for this is to use 'Stop Simulation' block, which is documented in the following link: https://www.mathworks.com/help/simulink/slref/stopsimulation.html?
You can generate an non-zero output from Test Sequence block when a specific state is reached and feed this to the 'Stop Simulation' block so you can stop the simulation.
2 Kommentare
Jonas Londschien
am 4 Okt. 2018
Bearbeitet: Jonas Londschien
am 4 Okt. 2018
Hello,
is this feature already added in 2018b? I am also interested in it, as an error will fail the test, and a extra block is annoying in a programmatic test created test sequence.
Denis Dmitriev
am 26 Nov. 2019
Hello,
Is this feature already added to R2019a?
Thanks,
Deni
Sebastian Castro
am 15 Okt. 2015
Bearbeitet: Sebastian Castro
am 15 Okt. 2015
You can use the error function inside the step you want. This will stop the simulation and output a custom error message.
error('My error message')
Another alternative is, when you reach the state, to change the value of an output signal from false to true. Then, connect this signal to a Stop Simulation block.
- Sebastian
1 Kommentar
Patrick
am 16 Okt. 2015
Todd
am 4 Mär. 2022
0 Stimmen
One method is to add an output signal that drives a Simulation Stop block.