Can you tell me what's wrong with the script I wrote for a Transfer function for a closed-loop feedback system with disturbances? Thank you.
3 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Ashkhen Aristakessian
am 29 Sep. 2015
Kommentiert: Ashkhen Aristakessian
am 30 Sep. 2015

This is the script I wrote for the transfer function for in the picture.
clear all;
figure;
for K = [5,10,50]
Tnum=[K K 0];
Tden=[1 16 21.5+K K+97.5];
T=tf(Tnum,Tden);
t=[0:0.1:10];
[y,t]=step(T,t);
plot(t,y);
hold on;
end
title('Unit Step Response for K= 5,10,50');
xlabel('Time(sec)'),ylabel('Step Response');
grid on;
grid minor;
I Know it is not correct because the output is not the same as the solution in the book. What am I doing wrong?

0 Kommentare
Akzeptierte Antwort
Madhu Govindarajan
am 29 Sep. 2015
If you look at your T it is a second order transfer function.
I think your Tnum should be [K K] and not [K K 0]
Weitere Antworten (0)
Siehe auch
Kategorien
Mehr zu Stability Analysis finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!