problem while tuning PID controller
Ältere Kommentare anzeigen
I try to tune a PID-Controller in Matlab2010b if i use a discrete one i get the error Message "The second input argument of the "d2d" command must be a positive scalar." if i use a continuous one i get "Input to SVD must not contain NaN or Inf." what i have to pay attention that this block works fine? My system can became NaN due to a Sqrt-expression....
Akzeptierte Antwort
Weitere Antworten (4)
Arkadiy Turevskiy
am 12 Dez. 2011
0 Stimmen
Can you provide the plant model?
Martin1986
am 13 Dez. 2011
0 Stimmen
Yoni
am 19 Jan. 2012
0 Stimmen
Hi Martin,
I've had the same problem.
It seems the discrete PID option does not handle a sampling time of "-1" (should have inherited the sampling time it that case)
So the workaround for your problem is to enter your own explicit expression for the sampling time. do not leave it on "-1".
This should eliminate the "The second input argument of the "d2d" command must be a positive scalar."
Cheers, Yoni
1 Kommentar
Nail
am 14 Mai 2018
Also, simulation time must not be set to "inf".