Sum of a signal in simulink
22 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Sam136
am 4 Aug. 2015
Bearbeitet: Yeow Yu Leong
am 9 Jun. 2024
In my Simulink model, current value of a signal should be added to all previous value of the same signal. I've used integrator with initial value of zero to find it; however the result is different from what I find in Matlab through "sum" or "trapz" function. The solver is continuous with fixed step size. Any thought to resolve this issue. or any other block to use for this purpose instead of integrator?
0 Kommentare
Akzeptierte Antwort
Azzi Abdelmalek
am 4 Aug. 2015
Bearbeitet: Azzi Abdelmalek
am 4 Aug. 2015
function y=fcn(u)
persistent a
if isempty(a)
a=0
end
y=u+a;
a=y;
You can also use a discrete transfer function 1/(z-1)
1 Kommentar
Weitere Antworten (1)
Sean de Wolski
am 4 Aug. 2015
You could also use a unit delay:

1 Kommentar
Azzi Abdelmalek
am 4 Aug. 2015
He is asking for all previous values. This will calculate out(n)+out(n-1)
Siehe auch
Produkte
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!