Halo everyone, I'm working on a high frequency converter using full bridge Mosfets configuration, with a switching frequency of 20Mhz. What I've noticed is that the higher the frequency, the slower the simulation gets.
For instance: At 20KHz, is simulates much much faster than at 20MHz.
I've attached a print screen of my solver settings.
Does anyone have any ideas why this is happening?
Thanks, Armando.
1 Kommentar
Omkar Dalvi
am 11 Sep. 2019
hie can u help me with a similar circuit. i am confused so as how to get higher frequency output for AC
Akzeptierte Antwort
Sebastian Castro
am 21 Jul. 2015
Bearbeitet: Sebastian Castro
am 21 Jul. 2015
That makes sense! If your frequency is higher, then there are more switching events per second that fire off zero-crossings in the Simulink solver.
It depends on what you're trying to do, though. If you're trying to model a fixed number of cycles, then you can also reduce the total simulation time. For example, 10 cycles at 20 MHz requires 1/1000th of the total simulation time than at 20 kHz.
If you need to simulate for a fixed time range, e.g., 10 seconds, then there isn't much of a workaround for that. Simulation will be slower if your switches go on-and-off 1000 times faster.
EDIT: Are you using SimPowerSystems or Simscape/SimElectronics? If you're using Simscape, I'd try the ode23t or ode15s solvers instead of ode23tb. If you're using SimPowerSystems, keep it as is.
- Sebastian
1 Kommentar
davood mansouri
am 18 Dez. 2017
Dear Sebastian Castro I have simulate inverter in SimPowerSystems. simulation speed is up, but by using a circuit breaker in the simulation it runs very slow. how can I speed up it?