Simscape model yeilds Simulink "State Derivative Fail" Error
4 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Uing the Simscape Pneumatic Piston Chamber Block in a simulation runs fine with area, extension and dead volume paramters set to .2m^2, 1m and 1e-5 respectivly. When I change to my actual device parameters of 28cm^2, 2.54cm and .7cm Simulink reports a State Derivative Fail error.
Why?
0 Kommentare
Antworten (1)
Sabin
am 23 Dez. 2025 um 17:24
This error indicates numerical instability in the simulation. When using a smaller area and stroke and a much larger dead volume relative to size, the system dynamics will change drastically likely increasing the stiffness. This can cause the solver to fail if the time step is too large or the model is too stiff for the default solver settings. Double-check your units and parameter values for consistency. If that's all correct try reducing the solver step size or switching to a ode23t or daessc solver (introduced in R2021a).
0 Kommentare
Siehe auch
Kategorien
Mehr zu Foundation and Custom Domains finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!