Here is my code for a counterflow water/water heat exchanger based on LMTD method.
The error which I am receiving is that no. of variables are exceeding the no. of equations. But I can't think of any equation which I missed as it is a very simple model. Can someone take a look at it and suggest any equation which I have missed.
________________________________________________
component counterflow_HX
% Heat Exchanger
% Ideal Counter flow heat exchanger based on LMTD method
nodes
A1 = foundation.thermal_liquid.thermal_liquid; % A1:left
B1 = foundation.thermal_liquid.thermal_liquid; % B1:left
B2 = foundation.thermal_liquid.thermal_liquid; % B2:right
A2 = foundation.thermal_liquid.thermal_liquid; % A2:right
end
parameters
Cp = { 4.2, 'J/g/K'}; % Specific heat
UA = { 0.34, 'J/s/K'}; % Product of heat transfer coefficient & area
end
variables
M1 = { 0.09, 'kg/s' }; % hot side mass flow
M2 = { 0.275, 'kg/s' }; % cold side mass flow
Phi1 = { 0, 'J/s' }; % hot side duty
Phi2 = { 0, 'J/s' }; % cold side duty
end
branches
M1 : A1.mdot -> B1.mdot;
M2 : A2.mdot -> B2.mdot;
Phi1: A1.Phi -> B1.Phi;
Phi2: A2.Phi -> B2.Phi;
end
equations
let
p_A1 = A1.p;
T_A1 = A1.T;
p_A2 = A2.p;
T_A2 = A2.T;
p_B1 = B1.p;
T_B1 = B1.T;
p_B2 = B2.p;
T_B2 = B2.T;
LMTD = ((T_A1 - T_B2) - (T_A2 - T_B1))/ (log ((T_A1 - T_B2) / (T_A2 - T_B1)));
in
Phi1 == M1 * Cp * (T_A1 - T_B1)
Phi2 == M2 * Cp * (T_A2 - T_B2)
Phi1 == Phi2
p_A1 == p_B1
p_A2 == p_B2
Phi1 == UA * LMTD
end
end
end
---------------------------------------------------------------
3 Kommentare
Akzeptierte Antwort
Weitere Antworten (0)