I have a model that simulates slowly. My model has many signals, many of them multidimensional or bus signals. When I simulate with Simulink Profiler, it does not show one clear block that is causing problems. Much of the time is "self time" in the model itself or model references. What could be causing this?
Akzeptierte Antwort
MathWorks Support Team
am 2 Dez. 2025 um 0:00
Bearbeitet: MathWorks Support Team
am 2 Dez. 2025 um 19:08
This could be time Simulink spends on diagnostics such as "Simulation Range Checking" and "Inf or NaN block output". Try disabling some of the run-time diagnostics that scale with the number of signals and see if that improves performance.
Also inspect the number of warnings being thrown by your model. Throwing warnings can be expensive and blocks simulation execution. If you have hundreds or thousands of warnings, consider addressing the root issue or disabling diagnostics to reduce them.
Both running diagnostic checks and throwing warnings are two common reasons for "self time" to be large but not the only ones. If you need additional assistance locating the root cause of large "self time" for a model, consider creating a case with MathWorks Technical Support.