Simscape fluids error cylinder area parametrization

35 Ansichten (letzte 30 Tage)
Apostolos
Apostolos am 31 Okt. 2025 um 14:30
Kommentiert: Yifeng Tang am 5 Nov. 2025 um 18:14
Hello i am a university student and i am trying to build a hydraulic system for a crane miniature. My hydraulic system has the my defined values but i am getting the error:
Error:An error occurred during simulation and the simulation was terminated
Caused by:
['test_hydraulics/Solver Configuration1']: At time 0.498629, one or more assertions are triggered. See causes for specific information.
Liquid volume must be greater than minimum physical volume. The assertion comes from:
Block path: test_hydraulics/Double-Acting Actuator (IL)1
Assert location:
o In between line: 242, column: 5 and line: 242, column: 11 in file: foundation.isothermal_liquid.elements.translational_mechanical_converter
o In between line: 386, column: 17 and line: 395, column: 39 in file: fluids.isothermal_liquid.actuators.double_actuator
I dont know what to do i tried editing the parameters and i noticed that when i change my actuator area paramters from m^2 to cm^2 it works.
I have not used a relief valve.
Thanks in advance!
  5 Kommentare
Apostolos
Apostolos am 1 Nov. 2025 um 18:47
no i just change the unit
Yifeng Tang
Yifeng Tang am 5 Nov. 2025 um 18:14
Most likely a parametrization error or it's the way you actuates the cylinder (e.g. prescribing a motion). The error message says the rod (R end) has moved in the negative direction (towards C) so much that it now beyond the minimum point, leading to an unphysical volume. This usually happens when the hydraulic pressure isn't building up to support the external load, or the external load is prescribed in an unphysical way, e.g. as a velocity sources. It's hard to tell without seeing the model.

Melden Sie sich an, um zu kommentieren.