Control System Designer: Inconsistent Controller Output Step Response
134 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I use the control system designer with e.g simple plant and controller:
s = tf('s')
G = 1/(s+1)
C = 1/s;
controlSystemDesigner(G,C);
and the default control system architecture

After adding the step reponses



I expected them to be the same responses (since du is probably 0).
The response
is correct, however
is wrong (unbounded) and differs from
:




Is this a bug?
Best regards
Markus
0 Kommentare
Antworten (1)
Paul
am 11 Sep. 2025 um 21:21
I can recreate these result and uc/r certainly looks incorrect. After exporting the systems to the base workspace I get:
>> tf(IOTransfer1)
ans =
From input "r" to output "u":
s + 1
-----------
s^2 + s + 1
Continuous-time transfer function.
Model Properties
>> tf(IOTransfer2)
ans =
From input "r" to output "uC":
s + 1
---------
s^2 + 2 s
IOTransfer2 surely is incorrect and I can't figure out how such a result was obtained.
13 Kommentare
Paul
vor etwa 15 Stunden
Have you received confirmation of bug, or other closure, from Mathworks tech support?