how to make AC or DC load vary on simulink?
4 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I am making a HESS (hybrid energy system storage) project based on battery supercapacitors on stand alone PV, but I am confused about how to make the load change when the program is running, I am using version 2018b and 2023b, in version 2018b there is no variable load, but in 2023b there is a ‘dynamic load’ variable load that can be used as an AC or DC load, but I cannot connect the port of the block to my DC bus, is there a solution or suggestion?
2 Kommentare
Walter Roberson
am 6 Jul. 2025
I suspect that on one side you have Simscape Electric blocks, and on the other side you have Simscape Electric Specialized Power System blocks. Specialized Power Systems is a seperate Simscape domain from regular Simscape Electric, and the two cannot be connected together without using convertor blocks.
Antworten (1)
Javier Gazzarri
am 8 Jul. 2025
Hello Muhammad,
Please let me know if this is an acceptable to you:
1) Connect the load signal to the MULTIPLY port of a Divide block
2) Measure the PV voltage and connect the voltage to the DIVIDE port of the Divide block
3) Connect the output of the divide block to a Controlled Current Source block and connect the latter to the PV
4) Add a 1/z or transfer function to the loop above if it generates an algebraic loop
Hope this helps.
Javier