short circuit modelling at time t=5sec feeding a Induction motor
8 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Hi,
I don't know how to model an short circuit feeding the mathematical Simulink model of an Induction motor. I would lile to switch at time t=5sec from the standard three phase 380V feeding voltage to an short circuit and se how the current of the model of IM varies in time.
I think that it should behave like a generator when the short circuit occures in the feeding line.
Could you possibly help me to model this?
I send you some pics for more clarity:
Here I have tried to switch the incoming voltage to zero at time t=5 sec but it's not the same as an shortciruited voltage source.

Could anyone help me ?
Thanks
0 Kommentare
Antworten (1)
Vinay
am 12 Jun. 2025
The 'Three-Phase Fault' block can be used to model short-circuit behavior in a system. Initially, the fault block remains open and, when triggered, it creates a low-resistance path between the phases and ground.
The parameter 'Ron' represents the impedance of the arc through which the fault current flows. It effectively acts as a low-resistance switch between the phases and ground (or between phases), activated at the specified fault time.
Please refer to the below documentation of 'Three - Phase' for more details:
I hope this helps!
0 Kommentare
Siehe auch
Kategorien
Mehr zu Electromechanical finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!