Synchronous Machine pu Fundamental field winding bases

7 Ansichten (letzte 30 Tage)
Hi, everyone,
I have a question regarding the SPS block "Synchronous Machine pu fundamental". I opened the block (configured in continuous) to visualize the equations and write the model of the equations in per unit system and I found a gain called SM.N that multiplies the field voltage (Vfd).
Could you help me to understand the addition of this gain and could you share resources to understand the per-unit system that it is using.
I add a screenschot.
Thank you

Akzeptierte Antwort

praguna manvi
praguna manvi am 13 Feb. 2025
Bearbeitet: praguna manvi am 15 Apr. 2025
You can refer to the documentation for the "Synchronous Machine pu Fundamental," which mentions that the "Vf" input is normalized with respect to the nominal field voltage so that a 1 pu input produces a 1 pu stator voltage at no load. This is why there is a "Gain Block." Here is the link to the documentation:
Additionally, for more information on the "pu units system", refer to the following link:
Hope this helps!

Weitere Antworten (0)

Kategorien

Mehr zu Electrical Block Libraries finden Sie in Help Center und File Exchange

Produkte


Version

R2024a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by