Problem with Power Systems onramp course

18 Ansichten (letzte 30 Tage)
mohamed
mohamed am 19 Dez. 2024 um 13:42
Kommentiert: mohamed am 20 Dez. 2024 um 12:01
Power Systems >ComponentsRepresent >Power Systems Components >(3/6) Synchronous>task 7
when I finsished everything in task 1 to 6 but at task 7 the problem my signal donsn't match the signal requirement
I dont know what I did wrong, I followed every instructions and complete it but this one is asking me to do a missing requirement that they never ask

Akzeptierte Antwort

Cris LaPierre
Cris LaPierre am 20 Dez. 2024 um 4:02
You Synchronous Machine Salient Pole block does not look correct. You have 3 outputs on the right. You should only have 2. Specifically, the n port should not be showing.
From the doc, "To enable this port, set Zero sequence to Include.".
It looks like you missed the 2nd item in Task 1. Zero sequence should be set to Exclude. It appears this is not assessed so wasn't caught earlier. Make this change and your model should pass.