Field-Weakening Control with MTPA

5 Ansichten (letzte 30 Tage)
Bhagyesh
Bhagyesh am 20 Nov. 2024
Bearbeitet: Bhagyesh am 8 Dez. 2024
Hey Community,
I am trying to implement Field-Weakening Control with MTPA
As this example https://in.mathworks.com/help/mcb/gs/field-weakening-control-mtpa-pmsm.html supports QEP encoder sensor. How to integrate this example with Hall sensor. What paarmeter needs to change.?
Additionaly how to update PID tuning parameters.
Thanks in advance.

Akzeptierte Antwort

praguna manvi
praguna manvi am 26 Nov. 2024
To implement Field-Weakening Control with a Hall Sensor for an Interior PMSM, you can follow the changes outlined in the example of Field Orientation Control using a Hall Sensor with respect to a QEP sensor at the following link, which includes calibration and control logic changes:
For fine-tuning the PID in the example, you can adjust the “Discrete PI Controller" blocks. For more information on that, refer to the following documentation:
Hope this helps!
  1 Kommentar
Bhagyesh
Bhagyesh am 28 Nov. 2024
Thanks @praguna manvi for your answar.
I am following the same link for FWC. I wanted to understand how hall sensor is configured as interupt in this example? https://in.mathworks.com/help/mcb/gs/foc-pmsm-using-hall-sensor-example.html
Do I need to follow the same as an interupt or just adding Hall Validity block, Hall speed and Polistion block in FWC example?
Awating for your valuable feedback.
Thanks.

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (0)

Tags

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by