Can "pipe(G)" block be used to model forced air convection?

11 Ansichten (letzte 30 Tage)
SUDEEP SINGH RAWAT
SUDEEP SINGH RAWAT am 11 Jun. 2024
Kommentiert: Yifeng Tang am 29 Jun. 2024 um 21:03
Hello,
i am trying to model a battery pack with forced air convection cooling. The pipe(G) block can be used to transfer heat from gas flowing inside a pipe to intended surface geometry. But it is internal flow. My concern is i want to model heat transfer from the surface to the gas(air). But that will become external flow problem. Is it possible to do so?
please help!
thanks.

Akzeptierte Antwort

Yifeng Tang
Yifeng Tang am 11 Jun. 2024
I think it's possible. The combination of cross section and hydraulic diameter will give you a circumference; that multiplied by the pipe length is the total heat transfer area. So I would say it's possible.
  9 Kommentare
Yifeng Tang
Yifeng Tang am 29 Jun. 2024 um 21:01
If the heat transfer is happening between the air gap and the cell wall, I think the perimeter should be 2*3*h in your equation.
Yifeng Tang
Yifeng Tang am 29 Jun. 2024 um 21:03
But, keep in mind, this is an approximation at best, because I think your formulation is more appropriate for "cubic" shape cells. The gap shown in the picture is really the minimum gap.