- Locate the data object "ABC" in your model. This could be a signal, parameter, or any other data object defined in your workspace or model.
- Check the properties of the data object "ABC".
- Change the "DataScope" property from "File" to either "Auto" or "Exported".
Build failed happen when convert subsystem to model reference
7 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I have 1 model with top level is a subsystem, i can success build it. But, when i converted that subsystem to a model reference, build failed happen with this information;
Error: Invalid data scope setting 'File' for data object 'ABC' when code is generated for model 'ABC'. The data object is either used in more than one file in the generated code, has no readers or writers, or is a signal that is connected to a root input/output port. Modify the data scope of the data object to either 'Auto' or 'Exported'.
0 Kommentare
Antworten (1)
Omega
am 2 Aug. 2024
Hi Bui,
The error you're encountering typically occurs when the data scope setting for a signal or parameter is not compatible with the requirements of code generation for a model reference. Specifically, the error message indicates that the data object "ABC" has an invalid scope setting of "File".
You can fix the error by following the steps mentioned below:
To learn more about the Storage Classes you can refer to the following documentation link:
Storage Classes for Parameters and Signals Used in Model Blocks
0 Kommentare
Siehe auch
Kategorien
Mehr zu Deployment, Integration, and Supported Hardware finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!