variable duty ratio to a switch at different time intervals
13 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
KESARI HANUMANTHU
am 12 Apr. 2024
Kommentiert: Manikanta Aditya
am 13 Apr. 2024
I want to supply a gate pulse to an IGBT switch in DC-DC converter with a duty ratio of 40% from 0 to 2 seconds and 2 to 4 seconds with simulation time of 6 seconds and i want to disconnect the gate pulse to switch from 4 to 6 seconds. how to do this in simulink. The switching frequency of IGBT switch is 20 kHZ.
6 Kommentare
Fangjun Jiang
am 12 Apr. 2024
@Manikanta Aditya, which Pulse Generator block are you referring to? I didn't find the place to "Define Variable Duty Ratio in Pulse Type Attributes".
Manikanta Aditya
am 13 Apr. 2024
I meant the Pulse Generator block in Simulink that allows defining a variable duty ratio based on time.
Akzeptierte Antwort
Fangjun Jiang
am 12 Apr. 2024
I assume this is in Simulink. You can use an AND logic block or Product block to multiply two signals. One is the regular 40% duty cycle PWM all the time, the other is this On/Off signal based on pre-determined timing or based on event by other Simulink signal.
3 Kommentare
Fangjun Jiang
am 12 Apr. 2024
You could use a Signal Builder block. Or use a Switch block, before t<4, pass the PWM. After that, switch to 0.
Weitere Antworten (0)
Siehe auch
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!