Cross Correlation and time lag

So in my project work, i placed two accelerometers on a single vibrating body and i want to find the timelag between the signals at either end...
[Correlation,lag]=xcorr(voltage1,voltage2);
corrlength=numel(Correlation);
[mag,Index] = max(abs(Correlation));
sampletime=0.003 ;%data acquisition
timelag=lag(Index)*(sampletime);
------------------------------------- voltage1 and voltage2 are bandpassed signals from the accelerometers in a specific noise range
But everytime i run the function, the timelag and lag amounts to zero, no matter how much i adjust the accelerometer sensitivity and position. Is it supposed to be zero? Or am i doing something wrong?

3 Kommentare

dpb
dpb am 19 Apr. 2015
" Or am i doing something wrong?"
Probably, but we can't tell. Possibly the resolution of the data acq at the sampling rate and with whatever filtering your using combined with the size and design of the structure is such that there is no discernible time lag between the two locations. 3 msec dt--> only 333 Hz which ain't much bandwidth--would have to be a very large structure it would seem.
Jade Sen
Jade Sen am 19 Apr. 2015
oh thanks, ill try increasing the sampling rate then. Im using a simple second order butterworth bandpass, btw.
dpb
dpb am 20 Apr. 2015
I'd start by looking at the two raw data signals with a scope triggered off the input first, then Accel A and see if the experimental setup is ok first...

Melden Sie sich an, um zu kommentieren.

Antworten (0)

Kategorien

Mehr zu Audio I/O and Waveform Generation finden Sie in Hilfe-Center und File Exchange

Gefragt:

am 19 Apr. 2015

Kommentiert:

dpb
am 20 Apr. 2015

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by