Confusing THD value for a Signal without Harmonics
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
weinan
am 5 Mär. 2024
Kommentiert: weinan
am 6 Mär. 2024
When I use the offical example 'Determine THD for a Signal with Two Harmonics', I change the reference signal without harmonics and change the fundamental frequency from 100Hz to 8Hz, shown as follows:
t = 0:0.001:1-0.001;
x = 2*cos(2*pi*8*t);
Next, obtain the total harmonic distortion explicitly and using thd
r = thd(x,1000,10)
which yields r = -58.9845 dB, almost 11% THD rate!
Why a simple sinusoidal wave can cause such a THD rate using thd function?
0 Kommentare
Akzeptierte Antwort
David Goodmanson
am 5 Mär. 2024
Bearbeitet: David Goodmanson
am 5 Mär. 2024
Hi weinan,
MODIFIED
The thd process widens the peaks, as shown by the plot produced when you invoke thd. When the frequency is as small as 8 Hz, the left hand side of the peak is cut off a 0 frequency (first plot) and the code picks the second peak at the nonpeak spot that you see. If you raise the frequency to, say, 20 Hz (second plot), all the peak is included in the plot and and the resulting thd is -296.41 dB which is small by any standard.
3 Kommentare
David Goodmanson
am 5 Mär. 2024
Hi weinan, after I understood the issue I went back and modified the answer.
Weitere Antworten (0)
Siehe auch
Kategorien
Mehr zu Spectral Measurements finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!