Dataflow Conversion Error when generating hdl code from simulink
Ältere Kommentare anzeigen
I try to generate HDL Code form Simulink Subsystem Block and then it shows an error when I try to run from HDL Workflow Advisor in section 3.2 Generate RTL Code and Testbench. Here's an error
Failed Error:Dataflow conversion error: Function2SubsystemConverter.evalExpression: 0: variable description not found for the specified loop iteration
Error:Dataflow conversion error: Function2SubsystemConverter.evalExpression: 0: variable description not found for the
specified loop iteration
Error in slhdlcoder.HDLCoder/runPIRTransformAndCodegen
Error in slhdlcoder.HDLCoder/makehdl
Error in downstream.DownstreamIntegrationDriver/runGenerateRTLCodeAndTestbench
Error in runGenerateRTLCodeAndTestbench
Error in Simulink.ModelAdvisor/executeCheckCallbackFct
Error in Simulink.ModelAdvisor/run
Error in Simulink.ModelAdvisor/runCheck
Error in ModelAdvisor.Node/runTaskAdvisor
Failed Generated HDL code.
Antworten (1)
Kiran Kintali
am 28 Feb. 2024
Bearbeitet: Kiran Kintali
am 5 Mär. 2024
0 Stimmen
This is an unexpected error and seems related to this bug report.
2 Kommentare
Marshanda Febriana
am 29 Feb. 2024
Kiran Kintali
am 29 Feb. 2024
Bearbeitet: Kiran Kintali
am 5 Mär. 2024
This unexpected error is encounteded due to sum function with 3D inputs does not seems to be implemented yet in this HDL Coder workflow. I have created an enhancement request to the development team to address this issue.
For now please consider splitting the matrix manually for 'add', you can do something like x(:,:,1)+x(:,:,2)+x(:,:,3) should work.
Please share the model with the respective fix if you continue to run into other issues.
Hope this helps.
Kategorien
Mehr zu Code Generation finden Sie in Hilfe-Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!