Different Thyristor Gate width gives different waveforms.
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
In the below fully controlled converter, if I give Thyristor pulse width as 10% gives an incorrect output waveform.
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1558734/image.png)
It gives following waveform for 10% Duty ratio. (2 cycles are shown)
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1558739/image.png)
But for 50% duty ratio it gives the correct desired waveform. (2 cycles are shown)
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1558744/image.png)
Can someone please explain me what is the reason for that?
Thank you in advance.
0 Kommentare
Antworten (1)
Joel Van Sickel
am 6 Dez. 2023
Are you sure the results are wrong? You don't have a dc-link capacitor to maintain the dc voltage and with the inductive load and inductive transmission line, the thyristors can't turn off until current goes to zero regardless if the voltage goes negative.
0 Kommentare
Siehe auch
Kategorien
Mehr zu Specialized Power Systems finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!