Is the counter here working properly?
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
Dongxu Guo
am 30 Nov. 2023
Beantwortet: Dongxu Guo
am 1 Dez. 2023
I am trying to simulate a system in Simulink as shown below. It's kindof like a sigma-delta modulator. The two switches act like comparators - when the error exceeds the upper limit, +d becomes 1, otherwise it remains 0; when the error exceeds the lower limit, -d becomes 1, otherwise it remains 0. Both counters are set to count up, when there's rising edge from +d/-d.
Now the system is not working as I expected, and I noticed some weired behaviour of the counter at the top: +d only has one rising edge but the counter starts to count even before the rising edge. Is the counter working properly, or I'm doing something wrong? I've also attached the simulink model if it helps.
3 Kommentare
madhan ravi
am 30 Nov. 2023
Have a look at Triggered and Enabled subsystem, when you respond just post the output signal scope that you would like to achieve for the specified inputs.
Akzeptierte Antwort
Weitere Antworten (0)
Siehe auch
Kategorien
Mehr zu Schedule Model Components finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!