PMLSM force and back-EMF constant
10 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
PMLSM block's description defines an equality of force and back-EMF constants. But such equality is correct for single phase of linear motor only, isn't it? In this case, catalogue force and back-EMF constants must be reduced to single phase ones.
0 Kommentare
Antworten (2)
Sabin
am 4 Jun. 2025
Bearbeitet: Sabin
am 4 Jun. 2025
The back EMF constant is the peak voltage induced by the permanent magnet in the per-unit rotational speed of each of the phases. The force constant is the peak force induced by the per-unit current of each of the phases. It is numerically identical in value to the back EMF constant when both are expressed in SI units.
Yahav
am 23 Jul. 2025
Bearbeitet: Yahav
am 23 Jul. 2025
I understand that the definitions of the motor constants are:
Force constant: N/Apeak , BEMF constant: (Vphase peak)/(m/s)
I recommend adding this to the block help.
The block should yield the same results, regardless if using Force constant (Kf), BEMf constant (Kv), or Flux linkage constant (PM). However, this is not the case in the example model: "Three-Phase PMLSM Drive". The PMLSM block has force constant: 0.18 N/A, BEMF constant: 0.18 V/(m/s), and Flux linkage constant: 0.65 Wb. The model tuned to use the PM constant, but when switching to Kf or Kv, it yields different results and its not following the ref profile. Kfand Kv yields same results, but not equal PM
Attached is a modified model which includes a BEMF test at imposed speed. both Kf and Kv yields good results, but not the PM.
0 Kommentare
Siehe auch
Kategorien
Mehr zu Motor Drives finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!