Simulink, receive UDP packet wrong port width
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
Svenh
am 30 Okt. 2023
Bearbeitet: Stefanie Schwarz
am 9 Nov. 2023
To First state my current situation
In the following picture is my Simulink Model
The Error I get:
The Port width of the receive UDP BLock should be 25 but in the error it says that the byteunpack block only receives a input port width of 2.
My settings for the blocks are the following:
receive UDP packets Block (The IP-adress is filled in normaly, just not for the picture)
receive Block
Byte Unpack Block
What i tried
-changed the portwidth to different setting in the receive UDP Block but i get the same error
-tried to implement a selector Block, still got the same error
Thank you very much
0 Kommentare
Akzeptierte Antwort
Stefanie Schwarz
am 9 Nov. 2023
Bearbeitet: Stefanie Schwarz
am 9 Nov. 2023
When the Simulink Real-Time UDP blocks are used with Simulink messages, they automatically create a "UDP_Packet" bus definition in the base workspace. It seems that for the "Data" signal in that bus, the length is specified as 2, although it should be 25 as per the "Receive Width" specified in the UDP Receive block.
To fix this, just delete the "UDP_Packet" variable in the base workspace and update your model, so that the bus definition gets regenerated with the right length for the payload data.