Filter löschen
Filter löschen

MACRO Expansion in Targetlink Code

4 Ansichten (letzte 30 Tage)
Sulagna
Sulagna am 24 Aug. 2023
Kommentiert: Champuram Madhu am 3 Okt. 2023
I am trying to use a unit delay block where the initial condition of delay block is a macro, In the production code of Targetlink the Macro is automatically expanded to the value, i dont want that macro to expand in generated code. The block is inside a Lib file, so the entire code is not generated, only initial values are generated in main code.

Akzeptierte Antwort

Varun
Varun am 28 Aug. 2023
Hi Sulagana,
I understand the issue that the macro used to set initial condition of delay block is being expanded in the generated code.
In order to used it as a macro only without being expanded, you can follow below steps:
  1. Open unit delay block and set the initial condition with name lets say "myParam" and its value to be "Simulink.Parameter(100)”. Click OK.
  2. On the Code Generation tab, click the Code Mappings editor, set Storage Class of "myParam" to "Define". Click OK.
  3. To build the model and generate code, press Ctrl+B.
You can refer this documentation for more info: https://in.mathworks.com/help/ecoder/ug/macro-definitions-define.html
  3 Kommentare
Sulagna
Sulagna am 29 Aug. 2023
Is it possible using TargetLink as well?
Champuram Madhu
Champuram Madhu am 3 Okt. 2023
Hi
You could try creating a TargetLink DD variable with MACRO class.
In that case, it should be generated as a MACRO irrespective of the location

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (0)